هندسة السلامة ومنع الخسائر-غيرملون — الصفحة ٥٢

نسب العقوبات الملائمة لأخطار التشغيل العامة (GPH). جدول رقم (۱) DEFI Penalties for general process hazards (Dow chemical component, المصدر : (1976 A) 1 - Exothermic reaction: Hydrogenation, hydrolysis, isomerization, sulphonation and - = 50% penalty. 75% penalty. ncutralization... = 30% penalty. 2- Alkylation, amiration by ammonolysis, oxidation and polymerization condensation... 3- Halrganation 4 - Nitration...... B) Endothemic rection : C) 1 - 2- 3 - 4- D) = 125% penalty. Colcination, electrolysis, pyrolysis and cracking 20% penalty. Material handling and transter : Loading & unloading of class 1 flammable liquids or LPG (Flash Point less than 100 °F) = 50% penalty. Use of certrifuges, batch mixing in open containers, multiplicity of reactions in same equipment = 50% penalty. Processing combastible dusts, griding, blending, filters or drying = 50% penalty. Indoor warchousing and storage Class II cobustible liquids = 25% penalty. Combustible solides = 75% penalty. Class I flammable liquids = 100% penalty. Enclosed Process units: Processing flammble liquids of gases of location of dust colleators in buildings 30% penalty. ۵۲
ص ٥٢