0.665
1
T-T2 =
•X
1.004
0.387×103
= 1711.5 K
T3, = 1711.5 + 753.6 = 2465.1 K
Ans
=2162.1°C ←
Cut-off ratio,re
_V3_T3
-
V2 T2
2465.1
=3027
753.6
Air - standard efficiency=1-
1
=1-
100.4
=
3.2714-1
1.4 × (3.27-1)
-
r-1
r2 −1 | y(r. −1).
= 1−0.398 × 1.338 = 0.467
Ans
= 46.7% ⇐
Power output
=
= 0.467 × 66.5
nx total rate of heat added
=
31.1 kW
Power output /cylinder
=
Work done/cylinder/cycle
31.1 4
= 7.761W
7.76
=
-=0.3104 kJ
25
W 0.3104 × 1000
Pm
m
V 300 ×10-6
S
Ans
=
10.37 × 10 N/m2
X
As discussed in the text, this problem illustrates that for the san compression ratio and heat input Otto cycle is more efficient.