السجل العلمي للندوة العالمية لاستخدام تكنولوجيا الاشعاعات المؤينة 01-02 — الصفحة ٩٨٢

934 W.L. Whittemore and R.H. Chesworth flexible reactor core. In several cases, large quantities (several liters) of material to be irradiated have been placed in the pool just outside the reflector in beamports just at core edge where the flux is considerably larger than in the thermal column. In some instances, pure gamma radiation has been provided for these samples in the following operational mode. The reactor is operated for about one hour with the speci- mens removed and then is shut down. After a few minutes when the neutrons have died away, the samples are inserted into the pure gamma ray field. During the next 8 to 10 hours gamma ray doses of up to a megarad can be delivered at the core edge. Table 1. Summary of neutron and gamma ray fluxes for steady-state and pulsed operation 2 MW Steady State Operation Neutron flux (nv) 2000 MW Pulsed Operation Neutron Fluence (nvt)| 3.2x1014 Fast 9 x 1014 Location Central Thimble Thermal 5.6x10 Fast Gamma Rad/sec Gamma Thermal Rad 13 5.5x10 13 1 3 x 105 3.5 x 106 Pneumatic 13 1.0x101 13 1.0x10 9 x 104 14 1.8x10 3.8x10 14 1.1 x 106 Transfer Rotary 5.0x1012 4 x1012 2.4x104 1.3x1014 Rack 1.1x1014 2.9 x 105 Pool Out- 2.5x1012 4.0x1011 2.4x103 4.7x1013 1.2x1012 2.8 x 104 side Re- flector Figure 3 shows the University of Mainz Mark II TRIGA reactor Fig. 3. Radiochemistry experiments at the University of Mainz Mark II TRIGA reactor.
الكتاب — ص ٩٣٤

النص مستخرج آليًّا من صور الكتاب، وقد يقع فيه خطأ.