Some Geotechnical Problems in the Eastern Province of Saudi Arabia 803 TABLE 1 PHYSICAL AND MECHANICAL PROPERTIES OF SABKHAH Description Maximum Minimum Passing Sieve No. 75 mm, % 97 18 Natural Water Content, % 84.6 10 Liquid Limit %. 84 30 Plasticity Index, % 39 NP Bulk Density, gr/cc 1.89 1.34 Specific Gravity 2.51 SPT, blows/300 mm 2.82 6 0 0.54 0 0 2.16 1.08 0.95 0.39 Cohesion, kg/cm2 Angle of Friction, go 22 Initial Void Ratio Compression Index C Сс Note: 55 samples were tested. At the other location (4), the site investigation was carried out at the proper time, that is before construction began, though it was after the foundations were designed based on assumptions from a site nearby. At this location the loose to very loose silty shelly sand was not continuous and varied in thickness between 1 and 2-m within a top sand layer of about 4-m thick underlain by limestone, 1 to 2-m thick. The ground- water was at an average depth of 0.75-m below ground surface. The designers insisted that isolated footings exerting a net