مستخلصات رسائل السعوديين لدرجة الدكتوراة — الصفحة ٤١٩

Pure Sciences 265 60°C. The observed transfer constant CB.obs increases markedly with the ratio [styrene]/[methyl methacrylate]. The results are in quantitative agreement with a relation based upon a penultimate unit effect in the transfer reaction, in which it is assumed that the reaction rate is influenced by the nature of the penulti- mate unit, but not by the remaining units in the chain. When styrene (St) is the penultimate unit the transfer constant has been found to have the value 337, in substantial agreement with the work of Thomson and Walters and Gleixner et al at 60°C. When penultimate unit is methyl methacrylate (MMA) the transfer constant of the radical (~MMA-St.) towards carbon tetrabromide has been found to have the value 60. Experiments in the presence of inactive diluents have been carried out, to as- certain whether there is a significant influence of [St] on the derived values of CB,obs. The results revealed only a small dependence on the concentration, showing that complex-formation between halide and styrene (postulated by Breitenbach et al) is not significant in our work. 168 Ghonaim, Samir A., Some studies of molecular emission cavity analysis (EMECA). Birmingham University, 1974. In this thesis, various aspects of Molecular Emission Cavity Analysis are stu- died. A brief review of the distinction between atomic and molecular emissions precedes a description of the established MECA technique. Some on the appli- cation of the MECA technique for analytical purposes are extended. Modifica- tions of the basic technique are described which allow the range of elements which can be determined to be enlarged, and interferences to be removed. The major modifications which are described include an «oxy-cavity», a <<reaction vessel»> which can be used in conjunction with a MECA analysis, and an externaly cooled cavity. The <oxy-cavity» has been developed by introducing a stream of oxygen di- rectly into the cavity space. This modificatioin allows emissions derived from oxide species of boron, silicon, arsenic, antimony, and other elements to be contained within the cavity space. The use of a reaction vessel for a selective prevolatilization of the analyte followed by an introduction of the vapours into the cavity has been found to be particularly useful. It allows emissions to be sus- tained for spectral analysis as well as offering a means for removing various in- terferences. Some preliminary investigations are described using a water cooled cavity.
ص ٤١٩

النص مستخرج آليًّا من صور الكتاب، وقد يقع فيه خطأ.